LSZH Flame Retardant Polyolefin
Low Smoke Zero Halogen Flame Retardant Polyolefin Cable Materials (LSZH)
RYD series low smoke zero halogen flame retardant polyolefin cable materials meet the IEC61034/IEC60754 low smoke and halogen-free standards. Combustion does not produce harmful gases, low smoke and low heat release. Based on innovative surface treatment and mixing and dispersion technology, this product has excellent processability:less extrusion die residue, good wire diameter stability, fine surface, good wire scratch resistance, high strength and stress crack resistance,It has many advantages and is widely used in cable sheathing and insulation materials.
•General Cable Materials
Classification and standards |
Model
|
Feature description
|
Application
|
GB/T32129
UL1581
GB/T14864
YD/T1113
|
HF11-803
|
UL temperature rating 90℃, Oxygen Index ≥28
|
FT2,IEC60532-1 and VW-1 grade cable sheath and insulation such as network cables, optical fiber cables, signal cables, coaxial cables and other cables
|
HF11-802
|
UL temperature rating 90℃, flame retardant FT2,Oxygen Index≥30
|
HF11-D802
|
UL temperature rating 90℃, flame retardant IEC60332-1, Oxygen Index≥30
|
HF11-D802S
|
UL temperature rating 90℃, hardness 86A, flame retardant IEC60332-1,Oxygen Index≥30
|
|
•High Flame Resistance Cable Materials
Classification and standards |
Model
|
Feature description
|
Application
|
UL1685
|
HF11-801
|
UL temperature rating 90℃, flame retardan VW-1, CM and OFN
|
Cable insulation or sheath such as network cables, optical fiber
cables, signal cables, coaxial cables, power cables, and other cables with bundled combustion requirements
|
CPR EN50575
GB 31247
GB/T19666
|
HF11-B805
|
UL temperature rating 90℃, meets EN50575 B2ca flame retardant grade
|
HF11-C805
|
UL temperature rating 90℃, meets EN50575 Cca flame retardant grade
|
HF11-D805
|
UL temperature rating 90℃, meets EN50575 Dca flame retardant grade
|
|
• Railway Locomotive Cable Materials
Classification and standards |
Model
|
Feature description
|
Application
|
EN50264
EN45545 HL3
|
HF11-GM90
|
Temperature rating 90℃, not oil resistant, suitable for sheath
|
Train locomotive cable insulation and sheath
|
XF11-GMY05
|
Irradiation crosslinked, temperature rating 105℃, double oil resistance
|
|
• Shipboard Cable Materials
Classification and standards |
Model
|
Feature description
|
Application
|
IEC60092
EN45545 HL3
|
HF11-KM90
|
SHF1 type sheath, not oil resistant
|
Marine power, control, instrumentation
and telecommunication cable jacket
|
XF11-KMY05
|
Irradiation crosslinked, temperature rating 105℃, SHF2 type,double oil resistance
|
|